Weight | 0 kg |
country of origin | |
direction of flow | optional |
duty cycle | 100 % |
norm | ISO 5599-2 |
pilot air supply | external |
pilot pressure [bar] | 3÷10 |
type | solenoid valve |
valve function | 5/2-way, bistable, dominant |
working medium | Sprężone powietrze wg ISO8573-1:2010 [7:4:4] |
working pressure [bar] | -0,9÷10 |
VSVA-B-D52-ZTR-D2-1T1L FESTO
Solenoid valve (norm: ISO 5599-2)
Feature | Value |
---|---|
Valve function | 5/2 bistable-dominant |
Type of actuation | electrical |
Width | 52 mm |
Standard nominal flow rate | 2,900 l/min |
Operating pressure | -0.9 ... 10 bar |
Design structure | Piston slide |
Authorisation | C-Tick c CSA us (OL) c UL us - Recognized (OL) |
KC mark | KC-EMV |
CE mark (see declaration of conformity) | to EU directive for EMC |
Protection class | IP65 NEMA 4 |
Grid dimension | 59 mm |
Exhaust-air function | throttleable Via throttle plate Via individual sub-base |
Sealing principle | soft |
Assembly position | Any |
Conforms to standard | ISO 5599-2 |
Manual override | with accessories, detenting Pushing |
Type of piloting | Piloted |
Pilot air supply | external |
Flow direction | Any |
Signal status display | LED |
Pilot pressure | 3 ... 10 bar |
Flow rate of valve | 4,000 l/min |
Flow rate of valve on individual sub-base | 3,400 l/min |
Flow rate of pneumatically linked valve | 2,900 l/min |
Switching time reversal | 18 ms |
Duty cycle | 100 % |
Max. positive test pulse with logic 0 | 1,000 µs |
Max. negative test pulse with logic 1 | 3,500 µs |
Nominal breakaway current per solenoid coil | 165 mA up to 30 ms |
Nominal current with current reduction | 35 mA after 30 ms |
Characteristic coil data | 24 V DC: 4.6 W |
Surge strength | 2.5 kV |
Degree of contamination | 3 |
Permissible voltage fluctuation | +/- 10 % |
Operating medium | Compressed air in accordance with ISO8573-1:2010 [7:4:4] |
Note on operating and pilot medium | Lubricated operation possible (subsequently required for further operation) |
Vibration resistance | Transport application test at severity level 2 in accordance with FN 942017-4 and EN 60068-2-6 |
Shock resistance | Shock test with severity level 2 in accordance with FN 942017-5 and EN 60068-2-27 |
Corrosion resistance classification CRC | 0 - No corrosion stress |
Medium temperature | -5 ... 50 °C |
Relative air humidity | 0 - 90 % |
Ambient temperature | -5 ... 50 °C |
Product weight | 732 g |
Electrical connection | Plug-in as per ISO 5599-2 |
Mounting type | On sub-base |
Auxiliary pilot air port 12/14 | Connection plate size 2 as per ISO 5599-2 |
Pilot exhaust port 82/84 | Optional Not ducted as per standard Ducted |
Pneumatic connection, port 1 | Connection plate size 2 as per ISO 5599-2 |
Pneumatic connection, port 2 | Connection plate size 2 as per ISO 5599-2 |
Pneumatic connection, port 3 | Connection plate size 2 as per ISO 5599-2 |
Pneumatic connection, port 4 | Connection plate size 2 as per ISO 5599-2 |
Pneumatic connection, port 5 | Connection plate size 2 as per ISO 5599-2 |
Materials note | Conforms to RoHS |
Material seals | FPM HNBR NBR |
Material housing | Aluminium die cast PA |
Material screws | Galvanised steel |
manufacturer | FESTO |
dimensions | 0 x 0 x 0 |
Weight | 0 kg |
working pressure [bar] | -0,9÷10 |
norm | ISO 5599-2 |
type | solenoid valve |
country of origin | |
valve function | 5/2-way, bistable, dominant |
direction of flow | optional |
pilot air supply | external |
pilot pressure [bar] | 3÷10 |
duty cycle | 100 % |
working medium | Sprężone powietrze wg ISO8573-1:2010 [7:4:4] |
Technical materials
TKSA 11 SKF
K-22-B-E-C KUKKO
HDB26-8M30 SIT
Tr30x6 LH (FFR30AL) kołnierzowa, brąz CONTI